All-Flash CS 4014U´Â M&E, HPC, ºòµ¥ÀÌÅÍ¿Í °°Àº ¾ÖÇø®ÄÉÀ̼ÇÀÇ ³ôÀº 󸮷®°ú ªÀº Áö¿¬ ½Ã°£ ¿öÅ©·Îµå ¿ä±¸¸¦ ÃæÁ·Çϴ Ź¿ùÇÑ ¼º´ÉÀ» Á¦°øÇÕ´Ï´Ù. CS4014UÀÇ °¢ ³ëµå¿¡´Â 14°³ÀÇ U.2 SSD¸¦ ¼³Ä¡ÇÒ ¼ö ÀÖÀ¸¸ç, 5-³ëµå Ŭ·¯½ºÅÍ´Â ÃÖ´ë 20GB/s¸¦ ó¸®ÇÒ ¼ö ÀÖ½À´Ï´Ù. ÇÏÀ̺긮µå ±¸¼º¿¡¼ ¿Ïº®ÇÑ µ¥ÀÌÅÍ º¸È£, °í°¡¿ë¼º, ½Ç½Ã°£ SSD ¸ð´ÏÅ͸µ ¹× ÀÚµ¿ °èÃþÈ ±â´ÉÀ» Á¦°øÇÕ´Ï´Ù.
2U 14-bay
Ư¡ | ¼¼ºÎ »ç¾ç |
---|---|
Æû ÆÑÅÍ | 2U 14-bay |
³ëµå °³¼ö | 1 ~ 144 |
ÆÄÀÏ ½Ã½ºÅÛ | Infortrend Distributed File System (IDFS) |
ij½¬ ¸Þ¸ð¸® | ±âº» DDR4 64GB, ÃÖ´ë 256GB |
ÇÁ·ÐÆ®¿£µå ³×Æ®¿öÅ· (°¢ ³ëµå ´ç) | 10GbE (SFP+) x 2 or 10GbE (SFP+) x 4 or 25GbE (SFP28) x 2 or 40GbE (QSFP+) x 2 |
³»ºÎ ³×Æ®¿öÅ© (°¢ ³ëµå ´ç) | 10GbE (SFP+) x 2 or 25GbE (SFP28) x 2 or 40GbE (QSFP+) x 2 |
³×Æ®¿öÅ© À¯Çü Á¶ÇÕ |
Combination 1: Front-end (Onboard 10GbE x 2) + Internal (Onboard 10GbE x 2) Combination 2: Front-end (Onboard 10GbE x 4) + Internal (Host Board 25GbE x 2) Combination 3: Front-end (Onboard 10GbE x 4) + Internal (Host Board 40GbE x 2) Combination 4: Front-end (Host Board 25GbE x 2) + Internal (Host Board 25GbE x 2) Combination 5: Front-end (Host Board 40GbE x 2) + Internal (Host Board 40GbE x 2) Combination 6: Front-end (Onboard 10GbE x 4 + Host Board 25GbE x 2) + Internal (Host Board 25GbE x 2) Combination 7: Front-end (Onboard 10GbE x 4 + Host Board 40GbE x 2) + Internal (Host Board 40GbE x 2) |
µå¶óÀ̺ê ÀÎÅÍÆäÀ̽º | PCIe |
Áö¿ø µå¶óÀ̺ê | 2.5" U.2 SSD |
ÃÖ´ë µå¶óÀÌºê ¼ö | 74 |
µ¥ÀÌÅÍ º¸È£ |
µð½ºÅ© º¸È£: RAID 5, RAID 6 ³ëµå º¸È£: Erasure code (2+1 or 4+1 or 4+2 or 8+1 or 8+2) or Replica (x2 or x3) Ŭ·¯½ºÅÍ º¸È£: Rsync |
µ¥ÀÌÅÍ ¼ºñ½º |
±âº» ¼ÒÇÁÆ®¿þ¾î ±â´É:- SED (self-encrypting drives)- SSD cache: support 1 SAS/SATA SSD per node as read cache ¼±ÅÃÀû ¼ÒÇÁÆ®¿þ¾î ±â´É Ãß°¡ ¶óÀ̼¾½º ÇÊ¿ä:- WORM- Automated Storage Tiering - SSD cache: support 2,4,6 or 8 SAS/SATA SSD per node as read cache - Advanced DNS Load Balance: connection number, network throughput, CPU usage |
Áö¿ø ¿î¿µÃ¼Á¦ |
Windows Server 2016, Windows Server 2012 R2, CentOS 7.2 NoteÃֽŠȣȯ¼º Á¤º¸´Â EonStor DS Compatibility Matrix¸¦ ã¾ÆÁÖ¼¼¿ä. |
Áö¿ø ÇÁ·ÎÅäÄÝ | CIFS/SMB, NFS, FTP |
°ü¸® |
ACL Á¦¾î ÇÒ´ç·® °ü¸® »ç¿ëÀÚ °èÁ¤ °ü¸® À¥ ±â¹Ý EonOne °ü¸® ¼ÒÇÁÆ®¿þ¾î Microsoft Active Directory (AD)/Linux LDAP & NIS ÀÎÁõ ÀÚ¿ø Á¡À¯À² ºÐ¼®À» À§ÇÑ ½ºÅ丮Áö ÀÚ¿ø °ü¸® |
¾Ë¸² | Email, SNMP traps |
È®Àå ÀÎŬ·ÎÀú (JBOD) | JB 3016, JB 3060L |
°¡¿ë¼º ¹× ½Å·Ú¼º | SMB Multichannel, Self-healing |
¾ÈÀü ±âÁØ | ¾ÈÀü¼º: UL, BSMI, CB ÀüÀÚÆÄ ÀûÇÕ¼º: CE, BSMI, FCC |
ģȯ°æ ¼³°è |
¿¡³ÊÁö È¿À²ÀÌ 80% ÀÌ»ó Çâ»óµÈ 80 PLUS ÀÎÁõ Àü¿ø°ø±ÞÀåÄ¡ Áö´ÉÇü ¸ÖƼ·¹º§ µå¶óÀÌºê ½ºÇÉ ´Ù¿î |
Àü¿ø °ø±Þ ÀåÄ¡ |
Àü¿ø °ø±Þ: redundant and hot-swappable 530W x 2 (80 PLUS Bronze) AC voltage: 100VAC @10A to 240VAC @5A with PFC (auto-switching) Frequency: 50-60 Hz |
ȯ°æ |
¿Âµµ:- ÀÛµ¿: 5 ~ 40¡ÆC- ºñÀÛµ¿: -40 to 60¡ÆC °íµµ:- ÀÛµ¿: ÃÖ´ë ÇØ¹ß 3,660m (12,000ft)- ºñÀÛµ¿: ÃÖ´ë ÇØ¹ß 12,192m (40,000ft) »ó´ë ½Àµµ: 5 ~ 95% ºñÀÀÃà, ÀÛµ¿/ºñÀÛµ¿ »ó°ü ¾øÀ½ |
¼ºñ½º ¹× Áö¿ø |
Ç¥ÁØ ¼ºñ½º: 3³â°£ Á¦ÇÑµÈ Çϵå¿þ¾î º¸Áõ°ú 8x5 ÀüÈ, À¥ ¹× À̸ÞÀÏ Áö¿ø (¹èÅ͸® 2³â º¸Áõ)º¸Áõ ¿¬Àå: Ç¥ÁØ ¼ºñ½º 5³â±îÁö È®Àå °¡´É¼ºñ½º ¾÷±×·¹ÀÌµå ¿É¼Ç: ¾Æ·¡ ¼ºñ½º´Â 5³âÀ¸·Î ¾÷±×·¹ÀÌµå µÉ¼ö ÀÖ½À´Ï´Ù.- ¾÷±×·¹À̵å: ±³Ã¼ ºÎǰ ´ÙÀ½ ¿µ¾÷ÀÏ ¹ß¼Û- °í±Þ ¼ºñ½º: 24x7 ÀüÈ, À¥ ¹× À̸ÞÀÏ Áö¿ø + ´ÙÀ½ ¿µ¾÷ÀÏ Áø´Ü º¸°í - ÇÁ¸®¹Ì¾ö ¼ºñ½º: 24x7 ÀüÈ, À¥ ¹× À̸ÞÀÏ Áö¿ø + 4½Ã°£ ¾È¿¡ Áø´Ü º¸°í ±â¼ú Áö¿ø: ½Ã½ºÅÛ ¼³Ä¡ ¹× À¯Áö º¸¼ö Á¤º¸ Ãëµæ, ±â¼ú ¹®¼ ¹× ¼ÒÇÁÆ®¿þ¾î ´Ù¿î·Îµå, Áö¿ø ƼÄÏ ¹ß±ÞÇϱâÁ¦Ç° ¼ºñ½º Á¦Ç° µî·Ï, Æß¿þ¾î ´Ù¿î·Îµå, ¶óÀ̼¾½º ¼ºñ½º Á¢¼ö, Á¦Ç° ¼ö¸® ƼÄÏ ¹ß±Þ, Á¦Ç° ¼ö¸® »óÅ ȮÀÎ |
Å©±â (W x H x D) | 449 x 88 x 500 mm |
Æ÷Àå Å©±â (W x H x D) | 780 x 340 x 588 mm |