EonStor GS 3000U´Â ´ë·®ÀÇ 22 GB/s ¼øÂ÷Àû 󸮷®°ú ÃÖ´ë 1000K ´Ü¸» °£ IOPS¸¦ ÀÚ¶ûÇÏ´Â All-Flash U.2 SSD ÅëÇÕ ½ºÅ丮ÁöÀÔ´Ï´Ù. GS3025U´Â VDI ¹× M&E ½ºÆ®¸®¹Ö°ú °°Àº Àбâ ÀÛ¾÷·®ÀÌ ¸¹Àº ¾ÖÇø®ÄÉÀ̼ǿ¡ ÀûÇÕÇÕ´Ï´Ù. GS3024U´Â µ¥ÀÌÅͺ£À̽º, °¡»óÈ ¹× ºòµ¥ÀÌÅÍ ¾ÖÇø®ÄÉÀ̼ÇÀ» À§ÇÑ ÃÖ°íÀÇ °¡¼ººñ¸¦ Á¦°øÇÕ´Ï´Ù.
2U 24-bay
2U 25-bay
Ư¡ | ¼¼ºÎ »ç¾ç |
---|---|
¸ðµ¨ | GS 3024U GS 3025U |
Æû ÆÑÅÍ | 2U 24-bay 2U 25-bay |
ÄÁÆ®·Ñ·¯ | Dual-redundant or single upgradable to redundant |
ij½¬ ¹é¾÷ ±â¼ú | Super capacitor + Flash module (¾÷±×·¹À̵å Áö¿ø ½Ì±Û ÄÁÆ®·Ñ·¯ ¹× µà¾ó ÄÁÆ®·Ñ·¯ ¸ðµ¨ Àü¿ë) |
ij½¬ ¸Þ¸ð¸® |
2U 24-bay: ±âº» DDR4 16GB, ÃÖ´ë 128GB 2U 25-bay: ±âº» DDR4 16GB, ÃÖ´ë 512GB |
È£½ºÆ® º¸µå | Onboard host ports:- GS 3024U: 10GbE (SFP+) x 4 - GS 3025U: 10GbE (SFP+) x 8More host options:- 16Gb/s FC x 4- 32Gb/s FC x 2 or 4 - 10GbE (SFP+) x 2 - 10GbE (RJ-45) x 2 - 25GbE (SFP28) x 2 - 40GbE (QSFP+) x 2 - 12Gb/s SAS x 2 |
µå¶óÀ̺ê ÀÎÅÍÆäÀ̽º | PCIe |
Áö¿ø µå¶óÀ̺ê | 2.5" U.2 NVMe SSD |
µå¶óÀÌºê °í±Þ ±â´É | S.M.A.R.T. Áö¿ø ¹èµå¼½ÅÍ ÀÚµ¿ Àç¹èÁ¤ ¿¬°áµÈ µå¶óÀÌºê °¢°¢¿¡ Àü¿ë ´ë¿ªÆø |
ÃÖ´ë µå¶óÀÌºê ¼ö |
°¢ ¾îÇöóÀ̾ð½º: 896 (È®Àå ÀÎŬ·ÎÀú Ȱ¿ë) °¢ Ŭ·¯½ºÅÍ: 3,584 (¾îÇöóÀ̾𽺠Ȱ¿ë ¼öÆò È®Àå) |
RAID ¿É¼Ç | RAID 0, RAID 1, RAID 3, RAID 5, RAID 6, RAID 10, RAID 30, RAID 50, RAID 60 |
µ¥ÀÌÅÍ ¼ºñ½º |
±âº» ¼ÒÇÁÆ®¿þ¾î ±â´É:- Block-level scale-out- File-level scale-out (1* GS dual controller appliance within single cluster) - SED (self-encrypting drives) - Thin-provisioning (block-level) - Snapshot (block-level): 64 per source volume, 128 per system - Local replication: 4 per source volume, 16 per system - Remote replication (file-level): support Rsync with 128-bit SSH encryption ¼±ÅÃÀû ¼ÒÇÁÆ®¿þ¾î ±â´É Ãß°¡ ¶óÀ̼¾½º ÇÊ¿ä:- SSD cache (block-level, file-level)- File-level scale-out (from 2 to 4 GS appliance within a GS cluster) - Automated storage tiering (2 or 4 storage tiers based on drive types) - Advanced snapshot (file-level): 1024 per folder - Advanced local replication (block-level): 8 per source volume, 256 per system - Advanced remote replication (block-level): 8 per source volume, 64 per system |
Áö¿ø ¿î¿µÃ¼Á¦ |
Microsoft Windows Server 2019/2016/2012R2/2012/2008R2/2008 Windows 7 SP1 Windows 8.1 Microsoft Windows Hyper-V Red Hat Enterprise Linux SUSE Linux Enterprise Sun Solaris macOS X VMware Citrix XenServer OpenStack Cinder NoteÃֽŠȣȯ¼º Á¤º¸´Â EonStor DS Compatibility Matrix¸¦ ã¾ÆÁÖ¼¼¿ä. |
Áö¿ø ÇÁ·ÎÅäÄÝ |
File-level protocol: CIFS/SMB, NFS, AFP, FTP/FXP, WebDAV Block-level protocol: FC, iSCSI, SAS Object-level protocol: RESTful API |
Ŭ¶ó¿ìµå °ÔÀÌÆ®¿þÀÌ |
EonCloud Gateway´Â ´ÙÀ½ Á¦°øÀÚ¿Í Å¬¶ó¿ìµå ÅëÇÕ ±â´ÉÀ» Áö¿øÇÕ´Ï´Ù: - Amazon S3 - Microsoft Azure - Alibaba Cloud - Google Cloud - Baidu Cloud - Tencent Cloud - OpenStack - Wasabi - Yandex - hiCloud Note:ÀÚ¼¼ÇÑ Å¬¶ó¿ìµå Áö¿ø Á¤º¸´Â EonCloud Gateway¸¦ ã¾ÆÁÖ¼¼¿ä. |
³×Æ®¿öÅ© ±¸¼º |
IPv6 Áö¿ø °íÁ¤/À¯µ¿ IP ÁÖ¼Ò µà¾ó ±â°¡ºñÆ® ÀÌ´õ³Ý with Jumbo Frame Port trunking, NIC teaming, Link aggregation (IEEE 802.3ad) DHCP Ŭ¶óÀÌ¾ðÆ® MPIO, MC/S Áö¿ø |
°ü¸® |
»ç¿ëÀÚ °èÁ¤ °ü¸® ±×·ì °ü¸® Æú´õ °ü¸® - Æú´õ Á¢±Ù Á¦¾î ÇÒ´ç·® °ü¸® Microsoft Active Directory (AD)/Linux LDAP ÅëÇÕ AES Æú´õ ¾ÏÈ£È À¥ ±â¹Ý EonOne °ü¸® ¼ÒÇÁÆ®¿þ¾î ÀÚ¿ø Á¡À¯À² ºÐ¼®À» À§ÇÑ ½ºÅ丮Áö ÀÚ¿ø °ü¸® |
¾Ë¸² | Email, SNMP traps |
È®Àå ÀÎŬ·ÎÀú (JBOD) | JB 3012, JB 3016, JB 3024B, JB 3025B, JB 3060L |
°¡¿ë¼º ¹× ½Å·Ú¼º |
¸®´ø´øÆ®, ÇÖ½º¿Ò Çϵå¿þ¾î ¸ðµâ ÀåÄ¡ ¸ÅÇÎ Áö¿ø ¾ÈƼ¹ÙÀÌ·¯½º Trunk group Áö¿ø Cache Safe ±â¼ú UPS WORM (for file-level only) SMB ¸ÖƼä³Î |
¾ÈÀü ±âÁØ | ¾ÈÀü¼º: UL, BSMI, CB ÀüÀÚÆÄ ÀûÇÕ¼º: CE, BSMI, FCC |
ģȯ°æ ¼³°è |
¿¡³ÊÁö È¿À²ÀÌ 80% ÀÌ»ó Çâ»óµÈ 80 PLUS ÀÎÁõ Àü¿ø°ø±ÞÀåÄ¡ Áö´ÉÇü ¸ÖƼ·¹º§ µå¶óÀÌºê ½ºÇÉ ´Ù¿î |
Àü¿ø °ø±Þ ÀåÄ¡ |
Power supplies: redundant and hot-swappable - 2U 24-bay: 530W x 2 (80 PLUS Bronze) - 2U 25-bay: 800W x 2 (80 PLUS Platinum) AC voltage: PFC (auto-switching) - 2U 24-bay: 100VAC @10A to 240VAC @5A - 2U 25-bay: 100-127VAC @10A to 200-240VAC @5A Frequency: - 2U 24-bay: 50-60 Hz - 2U 25-bay: 47-63 Hz |
ȯ°æ |
¿Âµµ:- ÀÛµ¿: ¹èÅ͸® ¹é¾÷ À¯´Ö/ij½¬ ¹é¾÷ ¸ðµâ ¹Ì»ç¿ë ½Ã 0 ~ 40¡ÆC, »ç¿ë ½Ã 0 ~ 35¡ÆC- ºñÀÛµ¿: -40 to 60¡ÆC °íµµ:- ÀÛµ¿: ÃÖ´ë ÇØ¹ß 3,048 m (10,000 ft)- ºñÀÛµ¿: ÃÖ´ë ÇØ¹ß 12,192 m (40,000 ft) »ó´ë ½Àµµ: 5 ~ 95% ºñÀÀÃà, ÀÛµ¿/ºñÀÛµ¿ »ó°ü ¾øÀ½ |
¼ºñ½º ¹× Áö¿ø |
Ç¥ÁØ ¼ºñ½º: 3³â°£ Á¦ÇÑµÈ Çϵå¿þ¾î º¸Áõ°ú 8x5 ÀüÈ, À¥ ¹× À̸ÞÀÏ Áö¿ø (¹èÅ͸® 2³â º¸Áõ)º¸Áõ ¿¬Àå: Ç¥ÁØ ¼ºñ½º 5³â±îÁö È®Àå °¡´É¼ºñ½º ¾÷±×·¹ÀÌµå ¿É¼Ç: ¾Æ·¡ ¼ºñ½º´Â 5³âÀ¸·Î ¾÷±×·¹ÀÌµå µÉ¼ö ÀÖ½À´Ï´Ù.- ¾÷±×·¹À̵å: ±³Ã¼ ºÎǰ ´ÙÀ½ ¿µ¾÷ÀÏ ¹ß¼Û- °í±Þ ¼ºñ½º: 24x7 ÀüÈ, À¥ ¹× À̸ÞÀÏ Áö¿ø + ´ÙÀ½ ¿µ¾÷ÀÏ Áø´Ü º¸°í - ÇÁ¸®¹Ì¾ö ¼ºñ½º: 24x7 ÀüÈ, À¥ ¹× À̸ÞÀÏ Áö¿ø + 4½Ã°£ ¾È¿¡ Áø´Ü º¸°í ±â¼ú Áö¿ø: ½Ã½ºÅÛ ¼³Ä¡ ¹× À¯Áö º¸¼ö Á¤º¸ Ãëµæ, ±â¼ú ¹®¼ ¹× ¼ÒÇÁÆ®¿þ¾î ´Ù¿î·Îµå, Áö¿ø ƼÄÏ ¹ß±ÞÇϱâÁ¦Ç° ¼ºñ½º Á¦Ç° µî·Ï, Æß¿þ¾î ´Ù¿î·Îµå, ¶óÀ̼¾½º ¼ºñ½º Á¢¼ö, Á¦Ç° ¼ö¸® ƼÄÏ ¹ß±Þ, Á¦Ç° ¼ö¸® »óÅ ȮÀÎ |
Å©±â (W x H x D) |
»þ½Ã À̾î/µ¹ÃâºÎ Á¦¿Ü 2U 24-bay: 449 x 88 x 500 mm 2U 25-bay: 449 x 88 x 589.6 mm |
Æ÷Àå Å©±â (W x H x D) |
2U 24-bay: 780 x 338 x 588 mm 2U 25-bay: 794 x 369 x 596 mm |