12GB/s µå¶óÀ̺ê ÀÎÅÍÆäÀ̽º¸¦ °®Ãá EonStor GSe 1000 Series´Â CIFS/SMB, NFS, AFP ¹× FTP¿Í °°Àº ÆÄÀÏ ·¹º§ ÇÁ·ÎÅäÄÝ, ÆÄÀ̹ö ä³Î, iSCSI ¹× SAS¿Í °°Àº ºí·Ï ·¹º§ ÇÁ·ÎÅäÄÝ, °´Ã¼ ·¹º§ ÇÁ·ÎÅäÄÝÀ» ó¸®ÇÒ ¼ö ÀÖÀ¸¸ç, ÆÄÀÏ °íÀ¯ÀÇ URLÀ» ÅëÇØ Á÷Á¢ ÆÄÀÏ¿¡ ¾×¼¼½ºÇÏ°í µ¥ÀÌÅ͸¦ Ŭ¶ó¿ìµå·Î È®ÀåÇϰųª ¹é¾÷ÇÒ ¼ö ÀÖ½À´Ï´Ù. D2D2C¿¡¼ ¹é¾÷ µå¶óÀ̺ê·Î »ç¿ëÇÒ ¼öµµ ÀÖ¾î Ŭ¶ó¿ìµå¸¦ ½±°Ô ¾×¼¼½ºÇÒ ¼ö ÀÖ½À´Ï´Ù.
2U 12-bay
3U 16-bay
Ư¡ | ¼¼ºÎ »ç¾ç |
---|---|
¸ðµ¨ | GSe 1012 Gen2 GSe 1016 Gen2 EonStor GSe 1000 Gen1 ã±â |
Æû ÆÑÅÍ | 2U 12-bay 3U 16-bay |
ÄÁÆ®·Ñ·¯ | Single Controller |
ij½¬ ¹é¾÷ ±â¼ú | Super capacitor + Flash module (¼±ÅÃ) |
ij½¬ ¸Þ¸ð¸® | ±âº» DDR3 8GB, ÃÖ´ë 16GB |
È£½ºÆ® º¸µå | Onboard host ports:- 1GbE (RJ-45) x 4More host options:- 16Gb/s FC x 4- 32Gb/s FC x 2 - 1GbE (RJ-45) x 4 - 10GbE (SFP+) x 2 - 10GbE (RJ-45) x 2 - 25GbE (SFP28) x 2 - 40GbE (QSFP+) x 2 - 12Gb/s SAS x 2 Note:±¤¼¶À¯ ä³Î Point-to-Point/½ºÀ§Ä¡ ¸ðµå Áö¿ø |
µå¶óÀ̺ê ÀÎÅÍÆäÀ̽º | 12Gb/s SAS |
µå¶óÀ̺ê ȣȯ¼º |
2.5" SAS or SATA SSD 2.5" 10,000 or 15,000 RPM SAS HDD 3.5" 7,200 RPM Nearline SAS or SATA HDD NoteÃֽŠȣȯ¼º Á¤º¸´Â EonStor DS Compatibility Matrix¸¦ ã¾ÆÁÖ¼¼¿ä. |
µå¶óÀÌºê °í±Þ ±â´É | S.M.A.R.T. Áö¿ø ¹èµå¼½ÅÍ ÀÚµ¿ Àç¹èÁ¤ ¿¬°áµÈ µå¶óÀÌºê °¢°¢¿¡ Àü¿ë ´ë¿ªÆø |
ÃÖ´ë µå¶óÀÌºê ¼ö | 448 (È®Àå ÀÎŬ·ÎÁ® »ç¿ë½Ã) |
RAID ¿É¼Ç | RAID 0, RAID 1, RAID 3, RAID 5, RAID 6, RAID 10, RAID 30, RAID 50, RAID 60 |
µ¥ÀÌÅÍ ¼ºñ½º |
±âº» ¼ÒÇÁÆ®¿þ¾î ±â´É:- SSD cache- SED (self-encrypting drives) - Thin-provisioning (block-level) - Snapshot: 64 per source volume, 128 per system - Local replication: 4 per source volume, 16 per system - Remote replication (file-level): support Rsync with 128-bit SSH encryption ¼±ÅÃÀû ¼ÒÇÁÆ®¿þ¾î ±â´É Ãß°¡ ¶óÀ̼¾½º ÇÊ¿ä:- Automated storage tiering (2 or 4 storage tiers based on drive types)- Advanced snapshot: 256 per source volume, 4,096 per system - Advanced local replication (block-level): 8 per source volume, 256 per system - Advanced remote replication (block-level): 8 per source volume, 64 per system |
Áö¿ø ¿î¿µÃ¼Á¦ |
Microsoft Windows Server 2019/2016/2012R2/2012/2008R2/2008 Windows 7 SP1 Windows 8.1 Microsoft Windows Hyper-V Red Hat Enterprise Linux SUSE Linux Enterprise Sun Solaris macOS X VMware Citrix XenServer OpenStack Cinder NoteÃֽŠȣȯ¼º Á¤º¸´Â EonStor DS Compatibility Matrix¸¦ ã¾ÆÁÖ¼¼¿ä. |
Áö¿ø ÇÁ·ÎÅäÄÝ |
File-level protocol: CIFS/SMB, NFS, AFP, FTP/FXP, WebDAV Block-level protocol: FC, iSCSI, SAS Object-level protocol: RESTful API |
Ŭ¶ó¿ìµå °ÔÀÌÆ®¿þÀÌ |
EonCloud Gateway´Â ´ÙÀ½ Á¦°øÀÚ¿Í Å¬¶ó¿ìµå ÅëÇÕ ±â´ÉÀ» Áö¿øÇÕ´Ï´Ù: - Amazon S3 - Microsoft Azure - Alibaba Cloud - Google Cloud - Baidu Cloud - Tencent Cloud - OpenStack - Wasabi - Yandex - hiCloud Note:ÀÚ¼¼ÇÑ Å¬¶ó¿ìµå Áö¿ø Á¤º¸´Â EonCloud Gateway¸¦ ã¾ÆÁÖ¼¼¿ä. |
³×Æ®¿öÅ© ±¸¼º |
IPv6 Áö¿ø °íÁ¤/À¯µ¿ IP ÁÖ¼Ò µà¾ó ±â°¡ºñÆ® ÀÌ´õ³Ý with Jumbo Frame Port trunking, NIC teaming, Link aggregation (IEEE 802.3ad) DHCP Ŭ¶óÀÌ¾ðÆ® MPIO, MC/S Áö¿ø |
°ü¸® |
Á¢±Ù Á¦¾î ¸ñ·Ï °ü¸® ÇÒ´ç·® °ü¸® »ç¿ëÀÚ °èÁ¤ °ü¸® À¥ ±â¹Ý EonOne °ü¸® ¼ÒÇÁÆ®¿þ¾î Microsoft Active Directory (AD)/Linux LDAP ÅëÇÕ ÀÚ¿ø Á¡À¯À² ºÐ¼®À» À§ÇÑ ½ºÅ丮Áö ÀÚ¿ø °ü¸® |
¾Ë¸² | Email, SNMP traps |
È®Àå ÀÎŬ·ÎÀú (JBOD) | JB 3012, JB 3016, JB 3024B, JB 3025B, JB 3060L |
°¡¿ë¼º ¹× ½Å·Ú¼º |
Redundant, hot-swappable hardware modules Device mapper support Antivirus Trunk group support Cache Safe technology UPS WORM (for file-level only) SMB Multichannel |
¾ÈÀü ±âÁØ | ¾ÈÀü¼º: UL, BSMI, CB ÀüÀÚÆÄ ÀûÇÕ¼º: CE, BSMI, FCC |
ģȯ°æ ¼³°è |
¿¡³ÊÁö È¿À²ÀÌ 80% ÀÌ»ó Çâ»óµÈ 80 PLUS ÀÎÁõ Àü¿ø°ø±ÞÀåÄ¡ Áö´ÉÇü ¸ÖƼ·¹º§ µå¶óÀÌºê ½ºÇÉ ´Ù¿î |
Àü¿ø °ø±Þ ÀåÄ¡ |
Power supplies: redundant and hot-swappable 460W x 2 (80 PLUS Bronze) AC voltage: 100VAC @8A to 240VAC @4A with PFC (auto-switching) Frequency: 50-60 Hz Note:Power is also supplied in redundant mode, allowing the full operation with half the resources. |
ȯ°æ |
Temperature:- Operating: 5 to 40¡ÆC without BBU or CBM, 5 to 35¡ÆC with BBU or CBM- Non-operating: -40 to 60¡ÆC Altitude:- Operating: Sea level to 3,048m (10,000ft)- Non-operating: Sea level to 12,192m (40,000ft) Relative humidity: 5 to 95% non-condensing, operating or non-operating |
¼ºñ½º ¹× Áö¿ø |
Ç¥ÁØ ¼ºñ½º: 3³â°£ Á¦ÇÑµÈ Çϵå¿þ¾î º¸Áõ°ú 8x5 ÀüÈ, À¥ ¹× À̸ÞÀÏ Áö¿ø (¹èÅ͸® 2³â º¸Áõ)º¸Áõ ¿¬Àå: Ç¥ÁØ ¼ºñ½º 5³â±îÁö È®Àå °¡´É¼ºñ½º ¾÷±×·¹ÀÌµå ¿É¼Ç: ¾Æ·¡ ¼ºñ½º´Â 5³âÀ¸·Î ¾÷±×·¹ÀÌµå µÉ¼ö ÀÖ½À´Ï´Ù.- ¾÷±×·¹À̵å: ±³Ã¼ ºÎǰ ´ÙÀ½ ¿µ¾÷ÀÏ ¹ß¼Û- °í±Þ ¼ºñ½º: 24x7 ÀüÈ, À¥ ¹× À̸ÞÀÏ Áö¿ø + ´ÙÀ½ ¿µ¾÷ÀÏ Áø´Ü º¸°í - ÇÁ¸®¹Ì¾ö ¼ºñ½º: 24x7 ÀüÈ, À¥ ¹× À̸ÞÀÏ Áö¿ø + 4½Ã°£ ¾È¿¡ Áø´Ü º¸°í ±â¼ú Áö¿ø: ½Ã½ºÅÛ ¼³Ä¡ ¹× À¯Áö º¸¼ö Á¤º¸ Ãëµæ, ±â¼ú ¹®¼ ¹× ¼ÒÇÁÆ®¿þ¾î ´Ù¿î·Îµå, Áö¿ø ƼÄÏ ¹ß±ÞÇϱâÁ¦Ç° ¼ºñ½º Á¦Ç° µî·Ï, Æß¿þ¾î ´Ù¿î·Îµå, ¶óÀ̼¾½º ¼ºñ½º Á¢¼ö, Á¦Ç° ¼ö¸® ƼÄÏ ¹ß±Þ, Á¦Ç° ¼ö¸® »óÅ ȮÀÎ |
Å©±â (W x H x D) |
»þ½Ã À̾î/µ¹ÃâºÎ Á¦¿Ü 2U 12-bay: 449 x 88 x 500 mm 3U 16-bay: 449 x 130 x 500 mm |
Æ÷Àå Å©±â (W x H x D) |
2U 12-bay: 780 x 379 x 588 mm 3U 16-bay: 780 x 423 x 588 mm |
¹«°Ô (HDD Á¦¿Ü) |
2U 12-bay: 26.63 lbs (12.08 kg) 3U 16-bay: 32.65 lbs (14.81 kg) |